Is there a quick-start guide for the OBD200 using the MR55?
set up an OBD200 using the MR55
A step-by-step guide to programming a new OBD-200 module with the MR-55 handheld: vehicle preset, initial odometer, bus number, and auto baud.
| MODULE OBD-200 | HANDHELD MR-55 | STEPS 9 | EST. TIME 10–15 min |
| FIG 01 BUS> 0009 / 000123 ODO> 12345.6 EHRS> 7890.1 IHRS> 2345.6 MR-55 read results for a connected OBD-200. |
WHAT YOU'RE CONFIGURING Setting Up a New OBD-200
The OBD-200 reports odometer, engine-hour, and bus data back to Fleetwatch. Before it goes into service, use the MR-55 handheld to tell it which vehicle preset to run, what the odometer currently reads, which bus number it's on, and to auto-detect the CAN bus rate. |
| BEFORE YOU BEGIN | Put the MR-55 into technician mode first, plug in the module, turn the ignition on, then press ID, NO, YES in order. The header changes to **Main Menu** when it works. Stay in this mode through all four sections below; if the header ever reverts, just repeat this step. |
| IMPORTANT NOTE | Always perform the auto baud as the final step during configuration. |
PROCEDURE AT A GLANCE
| PHASE 1 · STEPS 1–3 Vehicle Preset Program the module for this vehicle's Para or Non-Revenue preset. | PHASE 2 · STEPS 4–5 Initial Odometer Set the module's starting odometer to match the dashboard. | PHASE 3 · STEPS 6–7 Bus Number Assign the vehicle/bus number to the module. | PHASE 4 · STEPS 8–9 Auto Baud Auto-detect the CAN bus rate with the ignition on. |
|
1
|
Read the ModuleWith the MR-55 in technician mode, press 1 to read the OBD-200. Wait for the results to fully populate before continuing. |
|
2
|
Open CAN/OBD SetupPress CLEAR to open the configuration menu, then step down through the menus: 3 (Initial Values) → 4 (More) → 4 (CAN/OBD Setup) → 4 (More). Four menus deep, if you land somewhere unexpected, press CLEAR and start the sequence again. |
|
3
|
Select the Preset & ResetChoose Para Preset or NonRev Preset for the vehicle this module is being installed in. Once it's programmed, press “RESET” on the MR-55 to return to the main menu. |
|
4
|
Return to Initial ValuesRead the module again (1), press CLEAR for the configuration menu, then press 3 for Initial Values. |
|
5
|
Enter the Odometer & ResetPress 1 for Initial ODO, enter the dashboard reading, and press “SEND”. Press “RESET” when done to return to the main menu. This value is in tenths of a mile. If the dashboard doesn't show tenths, leave that last digit at 0. |
|
6
|
Open Set Bus#Read the module (1), press CLEAR for the configuration menu, then press 2 for “SET BUS#”. |
|
7
|
Enter the Number & ResetEnter the vehicle number and press “SEND”. Once it's set, press “RESET” on the MR-55 to return to the main menu. |
|
8
|
Open Auto BaudRead the module (1), press CLEAR for the configuration menu, press 3 for Initial Values, then 4 for More. |
|
9
|
Run Auto BaudSelect Auto baud (1) and press “SEND”. Ignition must be ON. Auto baud can't detect the CAN bus rate with the ignition off, the MR-55 will report a failure. |
| Need a Hand? For configuration failures, or if the module won't read after Step 9, call S&A Systems, Inc. | (972) 722-1009 x32 ASK FOR OBD-200 SETUP |