Program Odometer Source Filter with the MR55

Setting the odometer source filter after setting the odometer source configuration

Setting the Odometer Source Filter
JX200 with the MR-55 handheld
First, move the bus away from all fuel lane FRs and Gate FRs, into a parking lot for example.
Then put the MR-55 handheld in tech mode and set the odometer source filter to 239.
Work quickly. The MR-55 stays locked to the module for only 60 to 90 seconds. If it times out while you move through the menus, press RESET, read the module again and repeat the steps.
Step 1: Enter tech mode
From the Main Menu:
1.Press ID
2.Press NO
3.Press YES
The handheld is now in tech mode, indicated by the asterisks around Main Menu:
** MAIN MENU **
Stay in tech mode for the rest of the procedure.
Step 2: Read the module
1.Press 1 to read the module.
2.The Read Results screen appears, for example:
BUS> 0000/005082
ODO>       331.1
EHRS>        0.0
IHRS         N/A
From the Read Results screen, press CLEAR
3.Press 3 for INITIAL VALUES.
1. RF PARAMETERS
2. SET BUS#
3. INITIAL VALUES
4. GPS SETTINGS
Step 3: Go to the Odo Src Fltr setting
1.Press 4 for MORE.
1. INITIAL ODO
2. ODO SOURCE
3. ENGINE HOURS
4. MORE
2.Press 4 for CAN/OBD Setup.
1. IDLE HOURS
2. TIRE FACTOR
3. STANDARD CFGS
4. CAN/OBD Setup
3.Press 4 for MORE.
1. Auto baud
2. Bit Rate
3. EID or SID
4. MORE
4.Press 4 for MORE.
1. Interlock
2. 1939 Addr
3. 1939 Name
4. MORE
5.Press 1 for Odo Src Fltr.
1. Odo Src Fltr
2. Para Preset
3. NonRev Preset
Step 4: Enter 239
1.Type 2 3 9
2.Press SEND to program the module.
Step 5: Read again and confirm
1.Press CLEAR until you are back at the Main Menu.
2.Press 1 to read the module again, then press CLEAR
3.Go back to the setting: press 3 4 4 4 4 1
4.Confirm the setting shows 239, then press CLEAR to leave without changing it.