Why is my DeviceMaster offline but responding to ping tests?
DeviceMaster static IP test
|
💻 At the computer
You, running the ping on a computer on the same network as the DeviceMaster (such as the Fleetwatch server).
|
🔧 At the DeviceMaster
A technician who can unplug and reconnect the DeviceMaster’s power while you watch the ping.
|
Step 1: Start a Continuous Ping
Open Command Prompt: press the Windows key, type cmd, and press Enter. Then type the command below, using the DeviceMaster’s IP address:
192.168.1.50 is an example. Replace it with your DeviceMaster’s actual IP address. The -t keeps the ping running until you press Ctrl + C. Leave it running for the rest of the test.
Step 2: Unplug the DeviceMaster and Watch the Ping
Ask the technician to physically disconnect the DeviceMaster from its power source. While it’s powered off, watch the ping results. You’ll see one of two things:
Step 3: Reconnect Power and Check Again
If the replies stopped (Result B), have the technician reconnect the DeviceMaster to power. Give it a minute or two to start up, then watch the ping:
When replies return, verify that both of these are working:
|
✔ Everything works
The power cycle most likely resolved the issue.
|
✘ Still offline
The DeviceMaster may need to be replaced. Contact Fleetwatch Support.
|
Tip: See Which Device Is Answering
If you got Result A, you can see the MAC address of the device that’s answering. While the DeviceMaster is still unplugged and the ping is still getting replies, open a second Command Prompt window and run:
Compare the Physical Address to the MAC address printed on the bottom of the DeviceMaster. If they don’t match, it confirms another device has the IP. Give this MAC address to your network administrator to help them find that device. Comtrol DeviceMaster MAC addresses typically begin with 00-C0-4E.
This only works when your computer is on the same local network (subnet) as the DeviceMaster.
Quick Reference
| Ping result | Next step |
|---|---|
| Replies continue with the DeviceMaster unplugged | IP conflict. Contact your network administrator, with the DeviceMaster’s MAC address. |
| Replies stop when unplugged, return when plugged back in, and everything works | Resolved by the power cycle. |
| Replies stop when unplugged, and it’s still offline after power returns | The DeviceMaster may need to be replaced. Contact Fleetwatch Support. |